New: temperature, fans, power supplies and SSD health per server. View hardware health

Try it free

An inference server answers the requests to an AI model. But a running process does not mean the model is responding. That is why PeakNode checks the service the way a client would: status code, response time and whether the response names the expected model. If the service goes down or the model has been unloaded, you are notified.

Illustration of a 4U server with eight GPUs. Marked in orange is what the agent measures. GPU values: recorded on 8 October 2026. Airflow calculated.

What is Inference server monitoring?

Inference server monitoring with PeakNode means: the endpoint, that is the address of the service, is called at fixed intervals, and the response has to meet three conditions. The status code is correct, the response arrives within the timeout, and the text contains the name of the model that should be loaded. A simple process check is not enough, because the vLLM health route only reports that the server is running, not whether a model is loaded.

GPUs of the node hgx-02 in the portal: table of the eight NVIDIA H100 with utilization, memory usage, temperature, power draw and clock per card, below the utilization history per GPU.
Screenshot from the portal with sample data (German interface).

Inference servers in the portal

  • An uptime monitor calls the endpoint over HTTP and checks the status code and the expected text, optionally with custom headers and basic auth.
  • For endpoints in the internal network, a cron script checks in via heartbeat. If the check-in does not arrive, you get an alert.
  • The server agent uses GPU memory and utilization to show whether the weights are loaded and whether requests are coming in (see GPU server monitoring).

What PeakNode checks on an inference server

A model that was silently unloaded only gets noticed when the first request of the day fails. With one check per minute, you know beforehand.

Checks content, not just reachability

The uptime monitor compares the response with an expected text. If the model name is missing from /v1/models or /api/tags, the check has failed, even if the server responds with 200.

Response time per check

Every check stores the response time. If it rises over several days, you see it in the history before users complain. Timeouts from 1 to 25 seconds can be selected.

Protected endpoints

Custom request headers (for example Authorization: Bearer …), basic auth, HTTP method and request body can be set per monitor. A POST to /v1/chat/completions with a small prompt is also possible.

Heartbeats for jobs and internal services

Evaluations, indexing runs, batch inference: the script calls a heartbeat URL at the end. If the call does not arrive within the expected interval plus grace period, you are notified.

The GPUs of the inference server

The server agent reports memory and utilization per GPU. Memory in use shows that the weights are loaded. An alert rule such as “GPU below 5% utilization for more than 60 minutes” tells you: loaded, but no requests.

Notifications in your channels

Notifications via email, Microsoft Teams, Slack, Discord, Telegram or webhook. The all-clear follows automatically when the check succeeds again.

Example configuration: five checks for an inference server

Example

ServiceCallExpectationIntervalTimeout
vLLM, OpenAI-compatibleGET /v1/modelsStatus 200, response contains "id":"meta-llama/Llama-3.1-70B-Instruct"1 minute10 s
OllamaGET /api/tagsStatus 200, response contains "name":"llama3.1:70b"5 minutes5 s
Triton Inference ServerGET /v2/models/resnet50/readyStatus 2001 minute5 s
Text Generation InferenceGET /infoStatus 200, response contains "model_id":"mistralai/Mistral-7B-Instruct-v0.3"3 minutes10 s
Nightly evaluation runHeartbeat after a successful runCheck-in every 24 hours, grace period 2 hours--

One possible configuration, not measured values. Model names and paths are taken from the projects’ documentation.

Which route to check for each server

Not every health route takes the loaded model into account. The table lists, for each server, the route that makes sense in the uptime monitor and the text to check for.

ServerRouteWhat it tells youCheck in the monitor
vLLM (OpenAI-compatible server)GET /health and GET /v1/models/health only reports that the process is running. /v1/models lists the loaded models with id.Status 200 on /v1/models, response contains the model name
OllamaGET /api/tags and GET /api/ps/api/tags lists installed models, /api/ps the ones currently loaded. Ollama unloads models after a period of inactivity; this is normal behavior.Status 200 on /api/tags, response contains the model name. Check /api/ps only if the model should stay loaded permanently (keep_alive)
NVIDIA Triton Inference ServerGET /v2/health/ready, GET /v2/models/<name>/readyReady only responds with 200 once the server is ready. The model route reports the readiness of a single model.Status 200 on the model route
Text Generation Inference (TGI)GET /health and GET /info/info returns, among other things, the model_id of the loaded model.Status 200 on /info, response contains the expected model_id
llama.cpp (llama-server)GET /healthResponds with 503 while loading and with 200 only afterwards.Status 200
Any OpenAI-compatible endpointPOST /v1/chat/completionsA real mini request shows that inference is actually running, not just the listing.POST with a small prompt in the request body, status 200, response contains "finish_reason"

Routes according to the projects’ documentation, as of October 2026. The uptime monitor checks the expected text as a substring of the response. Checks run from two check locations, at intervals from 1 minute to 1 day, with timeouts from 1 to 25 seconds.

When the inference server cannot be reached from the internet

The uptime monitors of the cloud edition only check public targets. Private addresses such as 10.x or 192.168.x are rejected for security reasons. For internal services there are three options.

OptionHow it worksSuitable for
Reverse proxy with access protectionThe endpoint is made reachable through a proxy with basic auth or a token header; the monitor sends the credentials along.Endpoints that are meant to be reachable for external clients or partners anyway
Heartbeat from the insideA cron script on the server or in the network calls the endpoint locally and checks in at the heartbeat URL only on success. If the check-in does not arrive, PeakNode raises an alert.Purely internal services, no inbound connection needed
PeakNode On-PremiseThe platform runs in your network and checks internal addresses directly, including status pages on the intranet.Companies with several internal services and their own data storage

The server agent for GPU values is not affected: it sends from the inside out and needs no inbound connection.

Plans and pricing

Every endpoint is an uptime monitor, every job a heartbeat, every inference server with an agent a server monitor. The notification channels are included in all plans.

Proof of Concept

Free

For testing

  • 1 server monitor
  • 1 uptime monitor, 1 heartbeat
  • 1 status page
  • Data for 14 days
  • NodeCare

Premium Recommended

€149 per month

€1,490 per year

  • 10 server monitors
  • 50 uptime monitors, 50 heartbeats
  • 5 status pages, 1 team
  • Data for 1 year
  • NodeCare and NodeGuard

Enterprise

€490 per month

€4,900 per year

  • 50 server monitors
  • 250 uptime monitors, 250 heartbeats
  • 25 status pages, unlimited teams
  • Data for 1 year
  • NodeCare and NodeGuard

On-Premise

Price on request

Installation package for your own servers

  • No limits on monitors and GPUs
  • All data in your own network
  • NodeCare and NodeGuard
  • one-off, plus VAT

One server monitor is one server, regardless of how many GPUs it has. NodeCare is included in every plan, NodeGuard in Premium, Enterprise and On-Premise. All plans in detail

Set up in three steps

For a publicly reachable endpoint, setup takes about two minutes.

  1. Create an uptime monitor

    Sign up, open “Uptime monitors”, choose type HTTP(s), enter the URL of the model route, for example https://inference.example.com/v1/models, and choose the interval and timeout.

  2. Define the expectation

    Under the advanced settings, enter the expected status code 200 and the model name in the response body field. For protected endpoints, add the Authorization header.

    Response body contains:
    "id":"meta-llama/Llama-3.1-70B-Instruct"
  3. Choose channels, add a heartbeat

    Decide where alerts go. For batch jobs, create a heartbeat and call its URL at the end of the job. Monitors and heartbeats can be published on a status page for your team.

    curl -fsS https://peaknode.de/webhook-heartbeat/<CODE> >/dev/null

Frequently asked
questions about Inference server monitoring

Continue to:

What is inference server monitoring?

Regularly checking whether an inference server answers requests to the loaded model. PeakNode calls the endpoint and checks the status code, the response time and the model name in the response.

Why is the vLLM health route not enough?

The /health route responds with 200 as soon as the server process is running. It does not tell you whether a model is loaded. Only /v1/models lists the loaded models. That is why PeakNode checks this route and the model name in the response.

Ollama unloads my model after five minutes. Is that an error?

No, that is the default behavior controlled by the keep_alive parameter. Check /api/tags for the installed model. If the model should stay loaded permanently, set keep_alive accordingly and also check /api/ps.

Can PeakNode send a real inference request?

Yes. The uptime monitor supports POST with a custom request body and headers, for example a small prompt to /v1/chat/completions. Every check costs GPU compute time, so an interval of 5 or 10 minutes is usually more sensible here than 1 minute.

My inference server is in the internal network. Does this still work?

The uptime monitors of the cloud edition only reach public addresses. For internal services, use a heartbeat that a script in the network calls after a successful local check, a reverse proxy with access protection, or the on-premises edition, which checks internal addresses directly.

Which data does PeakNode store from my endpoint?

For each check the time, result, status code and response time. For a failed content check, also the response body, so you can see what the server returned instead of the expected text. The retention period depends on the plan.

Where are the checks run from?

From two check locations, in all plans. More on the uptime monitoring page.

How do I monitor vLLM without Grafana?

With an uptime monitor on /v1/models that checks whether the model name is in the response, and with a server monitor for GPU memory and utilization. PeakNode shows both in the portal; no dashboard of your own is needed. Metrics that vLLM itself exposes at /metrics are not read by PeakNode.

How do I monitor Ollama?

With an uptime monitor based on the “AI inference endpoint” template: it queries /api/tags and checks whether the expected model is in the list. If Ollama only runs in the internal network, a script reports the result of a local check through a heartbeat. GPU memory and utilization are reported by the agent of GPU server monitoring.

Monitor your first endpoint in two minutes

Create an account, enter the model route, define the expected model name. The Proof of Concept plan is free.

Matching hardware from Nelpx: Buy an LLM server · AI servers for businesses · Buy RTX PRO 6000 Blackwell Server Edition · Buy NVIDIA DGX Spark