All Sparks on one page
GPU utilization per device, memory in use, hottest device, total power and the number of GPUs below 5% utilization. So you see at once where capacity is free.
New: temperature, fans, power supplies and SSD health per server. View hardware health
A single DGX Spark on a desk does not need monitoring. Several Sparks in a team do: who is free, whose disk is full, which device has been silent since this morning? PeakNode shows utilization, memory, disk, temperature and power draw for every Spark and notifies you when a device goes down.
Illustration: the agent only sends outbound, over port 443. Can be rotated with the mouse.
DGX Spark monitoring with PeakNode means: every Spark gets a server monitor. An agent, a script that runs via cron on DGX OS, sends GPU utilization, memory, temperature, power draw, disk and network to the portal. All of a team’s Sparks appear on one page, with an offline alert after three missed intervals and threshold alerts per device.
Every Spark is a server monitor with its own token. All of them together appear on the “GPU nodes” page.
GPU utilization per device, memory in use, hottest device, total power and the number of GPUs below 5% utilization. So you see at once where capacity is free.
If a device sends no data for three intervals, it counts as offline and you are notified. When it reports again, the all-clear follows automatically.
Rules such as “GPU temperature above 80 °C” or “disk above 90%”, optionally only after several consecutive readings, so that short spikes do not trigger an alert.
Utilization, temperature and power as a time series, and on the Spark also the unified memory from the kernel. With date selection and export as CSV or JSON.
Every server monitor has its own access token. A compromised device reveals nothing but its own readings.
Notifications via email, Microsoft Teams, Slack, Discord, Telegram or webhook.
| GPU | Utilization | Memory | Temperature | Power | Clock |
|---|---|---|---|---|---|
| NVIDIA RTX PRO 6000 Blackwell (idle) | 0% | 0 / 95.6 GiB | 29 °C | 28.9 / 600 W | 180 MHz |
| NVIDIA RTX PRO 6000 Blackwell (under load) | 100% | 0.5 / 95.6 GiB | 53 °C | 360.8 / 600 W | 2,422 MHz |
| NVIDIA H100 80GB HBM3, card 3 of 8 (under load) | 100% | 3.6 / 79.6 GiB | 52 °C | 698 / 700 W | 1,905 MHz |
| NVIDIA GB10, DGX Spark (idle) | 0% | - · unified 0.3 / 116 GiB | 50 °C | 4.3 W · no limit | 208 MHz |
| NVIDIA GB10, DGX Spark (under load) | 96% | - · unified 0.4 / 116 GiB | 75 °C | 68.5 W · no limit | 2,483 MHz |
Cross-checked with nvidia-smi at the same moment. The GB10 reports no dedicated GPU memory, no power limit and no fan. On the Spark, the used unified memory comes from the Linux kernel.
| Reading | Source on the device | Frequency |
|---|---|---|
| GPU utilization, memory, temperature, power and limit, clock, fan | nvidia-smi (NVIDIA driver), per GPU. On the GB10 the driver reports no GPU memory, no limit and no fan (“-”); the unified memory then comes from the kernel. | at the selected interval, from 1 minute |
| MIG instances (partitioned GPUs) | nvidia-smi, section MIG Device | at the selected interval |
| CPU utilization and load average | /proc/stat, /proc/loadavg | averaged over the reporting interval |
| Memory, total and used | /proc/meminfo, in containers the cgroup limits | at the selected interval |
| Disk, total and used | df (root file system) | at the selected interval |
| Network: throughput and total volume since boot | /proc/net/dev, excluding loopback | averaged over the measurement window |
| System: model, cores, clock, operating system, kernel, uptime | /proc/cpuinfo, lscpu, /etc/os-release, /proc/uptime | with every report |
Intervals: 1, 5, 10, 15 or 30 minutes, depending on the plan. DGX OS ships with the NVIDIA driver and nvidia-smi, and the agent uses exactly this interface.
No root service, no inbound firewall rule. The Spark sends, the portal receives.
Sign up, open “Server monitors”, create a monitor named after the Spark and choose the reporting interval.
The command from the portal downloads the agent script with this device’s token and adds it to the crontab.
mkdir -p -m 700 /opt/peaknode && cd /opt/peaknode && printf 'header = "Authorization: Bearer <TOKEN>"\n' | curl -fsSL -K - "https://peaknode.de/server-monitor-code/<ID>?os=linux" -o peaknode.tmp && mv -f peaknode.tmp peaknode.sh chmod 700 peaknode.sh && (crontab -l 2>/dev/null | grep -v peaknode.sh; echo "* * * * * /bin/bash /opt/peaknode/peaknode.sh") | crontab -
From the first report you see the values. Set thresholds and choose where alerts go.
Continue to:
Every Spark gets its own server monitor with its own token. The “GPU nodes” page shows all devices side by side. Two Sparks connected via ConnectX-7 are two devices for monitoring purposes. Larger servers with eight cards are covered on the HGX B300 and B200 page.
Yes. The agent only needs bash, curl, awk and nvidia-smi. DGX OS is an Ubuntu-based system with the NVIDIA driver preinstalled, and nvidia-smi is part of it.
If three reporting intervals pass without a report, the portal marks the device as offline and notifies you through the selected channels. As soon as data arrives again, the all-clear follows.
The readings as JSON, together with the monitor’s token. If NodeGuard is switched on for the device, the security data listed on the security page is added. The portal cannot send commands to the device; the connection only goes from the Spark to the portal.
Yes. In containers the agent reports the assigned memory and CPU quota, not the values of the host system. Tested with cgroup v1 and v2.
Yes. On 15 October 2026 the agent ran on a rented DGX Spark (GB10, driver 580.173.02, in a container with 116 GiB of visible memory), cross-checked with nvidia-smi. GPU collection has also been verified on RTX PRO 6000 Blackwell, H100 and B300 with MIG.
The Proof of Concept plan is free and includes 1 server monitor, that is one Spark for testing. Premium costs €149 per month for 10 server monitors. All plans are listed under pricing.
On the device itself with nvidia-smi. With PeakNode the GPU temperature of every Spark appears in the portal, with history and, if you like, an alert above a threshold such as “GPU temperature above 80 °C”. The GPU nodes page names the hottest device of all Sparks.
Yes, through the Prometheus export at /api/metrics, retrieved with the account’s API key. It provides utilization, temperature and power per GPU, among other values; GPU memory is left out because the Spark uses unified memory. A plan with API access is required; details under API and webhooks.
Create an account, create a monitor, run one line on the device. The Proof of Concept plan is free.
Matching hardware from Nelpx: Buy NVIDIA DGX Spark · DGX Spark and GB10 systems compared · NVIDIA RTX Spark · Configure an AI workstation