Eight cards, eight rows
Utilization, memory, temperature, power and clock per GPU, plus the server totals. In the history, eight lines in their own colors, with date selection and export.
New: temperature, fans, power supplies and SSD health per server. View hardware health
An HGX server computes with eight GPUs. If one fails or slows down because of heat, it disappears in the server average. That is why PeakNode shows each of the eight GPUs individually, reports a missing card or a driver that no longer responds, and calculates the energy of the GPUs in kWh.
Illustration of a 4U server with eight GPUs. Marked in orange is what the agent measures. GPU values: recorded on 8 October 2026. Airflow calculated.
In PeakNode an HGX B300 is set up as one server monitor. The agent on the server reads all eight GPUs through nvidia-smi, the query tool of the NVIDIA driver, and sends the values per card. The portal shows the server under “GPU nodes” with its totals (average utilization, total memory, hottest card, total power, idle cards) and every GPU individually below. If the server reports fewer cards than expected or stops reporting, you get an alert.


With eight cards per server, what matters is not the average but the one card that deviates. That is why every GPU appears individually in the portal.
Utilization, memory, temperature, power and clock per GPU, plus the server totals. In the history, eight lines in their own colors, with date selection and export.
You store the expected number of GPUs. If the agent reports fewer, that is a critical event. If nvidia-smi does not respond within the timeout, the agent reports exactly that instead of hanging.
Xid messages, the NVIDIA driver’s error codes in the kernel log, are assigned to the card and rated by code. Critical ones include 79 (GPU has fallen off the bus), 48 (double-bit ECC), 63 and 64 (row remapping) and 74 (NVLink).
Whether a card is throttling because of heat, the power cap or a hardware slowdown appears as an event in the portal. It is raised after three consecutive reports, so that a short spike does not trigger an alert.
Every GPU below 5% utilization counts as idle, with duration. An alert “idle for more than 120 minutes” shows booked but unused capacity.
The portal adds up the measured GPU power over time, and with your electricity price per kWh also to costs. With 8 cards at a limit of up to 1,100 W each, as on the tested B300, that is up to 8.8 kW for the GPUs alone.
| System | Utilization | Memory | Temperature | Power | Clock |
|---|---|---|---|---|---|
| HGX node 8× H100 80GB HBM3, aggregate (load on 3 of 8 cards) | avg. 37.5% | 11,123 MiB / 637.2 GiB | hottest card 56 °C | 2,442.1 / 5,600 W | - |
| Same machine, one card under load | 100% | 3,701 MiB / 79.6 GiB | 55 to 56 °C | 697 to 699 / 700 W | 1,905 to 1,965 MHz |
| Same machine, one card idle | 0% | 4 MiB / 79.6 GiB | 20 to 26 °C | 67 to 71 / 700 W | 345 MHz |
| NVIDIA B300 SXM6 AC with MIG (1× 1g.34gb, 18 SM) | - (MIG does not report utilization per instance) | 123 / 31,232 MiB | 29 °C | 250.5 / 1,100 W | 2,032 MHz |
Cross-checked with nvidia-smi at the same moment. SXM cards have no fan speed; the portal then shows “-”.
| Reading | Source on the node | Frequency |
|---|---|---|
| Per GPU: utilization, memory used and total, temperature, power and limit, SM and memory clock, driver version | nvidia-smi --query-gpu, per card | at the selected interval, from 1 minute |
| MIG instances: profile, GPU instance, SM count, memory used and total | nvidia-smi -q and nvidia-smi -L | at the selected interval |
| Health per GPU: ECC errors, row remapping, PCIe link, throttle reasons, processes with memory | nvidia-smi -q and extended queries, where the card reports the fields | at the selected interval |
| Xid events with code, card and time | Kernel log (journalctl or dmesg), mapped via the PCI address | at the selected interval, new entries only |
| Node: CPU utilization, load average, memory, disk, network | /proc/stat, /proc/meminfo, df, /proc/net/dev, in containers the cgroup limits | at the selected interval |
| Energy: watt-hours per node from board power | Integration of the measured power in the portal | continuously |
Intervals: 1, 5, 10, 15 or 30 minutes. ECC, row remapping, HBM temperature and throttle reasons are provided by data center GPUs; consumer cards report “N/A”, and the portal then shows “-”.
For the agent, a server with 8 GPUs is a Linux system with an NVIDIA driver. The differences are in the values, not in the setup.
| System | For monitoring | Note |
|---|---|---|
| HGX B300 (8× B300 SXM6) | One server monitor, eight GPU rows, MIG instances if enabled | Power limit of the tested B300 SXM6 AC according to nvidia-smi: 1,100 W per card |
| HGX B200 (8× B200 SXM) | One server monitor, eight GPU rows | Same driver path as B300, not yet measured on our own hardware |
| HGX H100 / H200 (8× SXM) | One server monitor, eight GPU rows | H100 verified on 8 October 2026 on an 8-GPU node |
| DGX B300 / DGX B200 | Like HGX; the agent runs on DGX OS (Ubuntu-based) with the driver preinstalled | Nothing special for the agent, see also DGX Spark monitoring |
| PCIe server with 4 or 8 cards | One server monitor, one row per card, plus fan speed for actively cooled cards | RTX PRO 6000 Blackwell Server Edition verified |
For memory or TDP of the individual models, see the NVIDIA data sheets. This page only lists values the agent has measured itself.
An HGX server is one server monitor, whether it has four or eight GPUs. Uptime monitors, heartbeats, status pages, channels and NodeCare are included in all plans, NodeGuard from Premium.
Free
For testing
€149 per month
€1,490 per year
€490 per month
€4,900 per year
Price on request
Installation package for your own servers
One server monitor is one server, regardless of how many GPUs it has. NodeCare is included in every plan, NodeGuard in Premium, Enterprise and On-Premise. All plans in detail
No service, no open port. The server sends, the portal receives.
Sign up, open “Server monitors”, create a monitor for the server, choose the reporting interval and enter 8 as the expected number of GPUs.
The command from the portal downloads the agent script with this server’s token and adds it to the crontab. Run it as root so that the kernel log and the processes of all users can be read.
mkdir -p -m 700 /opt/peaknode && cd /opt/peaknode && printf 'header = "Authorization: Bearer <TOKEN>"\n' | curl -fsSL -K - "https://peaknode.de/server-monitor-code/<ID>?os=linux" -o peaknode.tmp && mv -f peaknode.tmp peaknode.sh chmod 700 peaknode.sh && (crontab -l 2>/dev/null | grep -v peaknode.sh; echo "* * * * * /bin/bash /opt/peaknode/peaknode.sh") | crontab -
From the first report you see all eight cards. Set thresholds (temperature, memory, idle time), store the electricity price and choose the channels.
Continue to:
Each of the eight GPUs individually: utilization, memory, temperature, power and clock, plus the server totals, hardware errors from the kernel log, idle time and energy. If a card is missing or the server stops reporting, you get an alert.
One. One server monitor corresponds to one server, regardless of how many GPUs it has. The eight cards appear as rows below it; the plans count servers.
Collection per GPU and the totals across eight cards were verified on an HGX server with 8× H100 SXM. The B300 was tested as a single B300 SXM6 AC with MIG, with values identical to nvidia-smi. A complete HGX B300 uses the same path; a test run on one is still pending.
MIG (Multi-Instance GPU) splits a data center GPU into separate instances with their own memory. With MIG enabled, nvidia-smi reports no utilization and no memory for the card as a whole. Instead, the agent reads the instances (profile, GPU instance, SM count, memory), and the portal shows them below the card. nvidia-smi does not provide utilization per instance; there the portal shows “-”.
NVLink errors appear as Xid 74 from the kernel log. The agent does not collect bandwidth per NVLink or InfiniBand counters.
It is based on the power that nvidia-smi reports per GPU, added up over the reporting intervals. Shorter intervals give more accurate values. CPUs, power supply losses and cooling are not included.
The readings as JSON over TLS, with the monitor’s token in the Authorization header. Host names and process names are included, model data or file contents are not. If NodeGuard is switched on for the server, the security data listed on the security page is added. A report is at most 1 MB. The portal cannot execute anything on the server.
No. The agent reads all eight GPUs through nvidia-smi and the Xid messages from the kernel log, both of which come with the NVIDIA driver. DCGM profiling metrics such as SM activity are therefore not included. The GPU server monitoring page explains the difference.
The agent reads the values of the eight GPUs through nvidia-smi and the kernel log. If ipmitool is installed and the server’s BMC is reachable over IPMI, the Linux agent version 11 or later also reads power supplies, fans, inlet temperature and server power every 3 minutes. NodeCare then reports a failed power supply or fan.
Create an account, create a monitor, run one line on the server. The Proof of Concept plan is free.
Matching hardware from Nelpx: Buy NVIDIA HGX B300 · Configure HGX B200 · NVIDIA B300 and B200 at a glance · H100, H200, B200, B300 compared · Configure an HGX system · Server colocation in Germany