New: temperature, fans, power supplies and SSD health per server. View hardware health

Try it free

An HGX server computes with eight GPUs. If one fails or slows down because of heat, it disappears in the server average. That is why PeakNode shows each of the eight GPUs individually, reports a missing card or a driver that no longer responds, and calculates the energy of the GPUs in kWh.

Illustration of a 4U server with eight GPUs. Marked in orange is what the agent measures. GPU values: recorded on 8 October 2026. Airflow calculated.

What is HGX B300 and B200?

In PeakNode an HGX B300 is set up as one server monitor. The agent on the server reads all eight GPUs through nvidia-smi, the query tool of the NVIDIA driver, and sends the values per card. The portal shows the server under “GPU nodes” with its totals (average utilization, total memory, hottest card, total power, idle cards) and every GPU individually below. If the server reports fewer cards than expected or stops reporting, you get an alert.

GPUs of the node hgx-02 in the portal: table of the eight NVIDIA H100 with utilization, memory usage, temperature, power draw and clock per card, below the utilization history per GPU.
Screenshot from the portal with sample data (German interface).

GPU servers in the portal

  • Tested on 8 October 2026 on an HGX server with 8× H100 SXM and on a B300 SXM6 AC with MIG, each against nvidia-smi.
  • With MIG, that is partitioned GPUs, the instances appear below the card with profile, memory and SM count.
  • After three missed reporting intervals a server counts as offline; the all-clear follows automatically.

What PeakNode monitors on an HGX server

With eight cards per server, what matters is not the average but the one card that deviates. That is why every GPU appears individually in the portal.

Eight cards, eight rows

Utilization, memory, temperature, power and clock per GPU, plus the server totals. In the history, eight lines in their own colors, with date selection and export.

Missing card, hung driver

You store the expected number of GPUs. If the agent reports fewer, that is a critical event. If nvidia-smi does not respond within the timeout, the agent reports exactly that instead of hanging.

Xid errors by severity

Xid messages, the NVIDIA driver’s error codes in the kernel log, are assigned to the card and rated by code. Critical ones include 79 (GPU has fallen off the bus), 48 (double-bit ECC), 63 and 64 (row remapping) and 74 (NVLink).

Why a card slows down

Whether a card is throttling because of heat, the power cap or a hardware slowdown appears as an event in the portal. It is raised after three consecutive reports, so that a short spike does not trigger an alert.

Idle time per card

Every GPU below 5% utilization counts as idle, with duration. An alert “idle for more than 120 minutes” shows booked but unused capacity.

Energy in kWh and euros

The portal adds up the measured GPU power over time, and with your electricity price per kWh also to costs. With 8 cards at a limit of up to 1,100 W each, as on the tested B300, that is up to 8.8 kW for the GPUs alone.

Recorded values: HGX server with 8 GPUs and B300 with MIG

Recorded on 8 October 2026

SystemUtilizationMemoryTemperaturePowerClock
HGX node 8× H100 80GB HBM3, aggregate (load on 3 of 8 cards)avg. 37.5%11,123 MiB / 637.2 GiBhottest card 56 °C2,442.1 / 5,600 W-
Same machine, one card under load100%3,701 MiB / 79.6 GiB55 to 56 °C697 to 699 / 700 W1,905 to 1,965 MHz
Same machine, one card idle0%4 MiB / 79.6 GiB20 to 26 °C67 to 71 / 700 W345 MHz
NVIDIA B300 SXM6 AC with MIG (1× 1g.34gb, 18 SM)- (MIG does not report utilization per instance)123 / 31,232 MiB29 °C250.5 / 1,100 W2,032 MHz

Cross-checked with nvidia-smi at the same moment. SXM cards have no fan speed; the portal then shows “-”.

All readings and their sources

The agent is a shell script that runs via cron. It reads nvidia-smi and the Linux kernel. Anything a source does not provide appears as “-”, never as zero.

ReadingSource on the nodeFrequency
Per GPU: utilization, memory used and total, temperature, power and limit, SM and memory clock, driver versionnvidia-smi --query-gpu, per cardat the selected interval, from 1 minute
MIG instances: profile, GPU instance, SM count, memory used and totalnvidia-smi -q and nvidia-smi -Lat the selected interval
Health per GPU: ECC errors, row remapping, PCIe link, throttle reasons, processes with memorynvidia-smi -q and extended queries, where the card reports the fieldsat the selected interval
Xid events with code, card and timeKernel log (journalctl or dmesg), mapped via the PCI addressat the selected interval, new entries only
Node: CPU utilization, load average, memory, disk, network/proc/stat, /proc/meminfo, df, /proc/net/dev, in containers the cgroup limitsat the selected interval
Energy: watt-hours per node from board powerIntegration of the measured power in the portalcontinuously

Intervals: 1, 5, 10, 15 or 30 minutes. ECC, row remapping, HBM temperature and throttle reasons are provided by data center GPUs; consumer cards report “N/A”, and the portal then shows “-”.

HGX B300, HGX B200 and DGX: what is the same for monitoring

For the agent, a server with 8 GPUs is a Linux system with an NVIDIA driver. The differences are in the values, not in the setup.

SystemFor monitoringNote
HGX B300 (8× B300 SXM6)One server monitor, eight GPU rows, MIG instances if enabledPower limit of the tested B300 SXM6 AC according to nvidia-smi: 1,100 W per card
HGX B200 (8× B200 SXM)One server monitor, eight GPU rowsSame driver path as B300, not yet measured on our own hardware
HGX H100 / H200 (8× SXM)One server monitor, eight GPU rowsH100 verified on 8 October 2026 on an 8-GPU node
DGX B300 / DGX B200Like HGX; the agent runs on DGX OS (Ubuntu-based) with the driver preinstalledNothing special for the agent, see also DGX Spark monitoring
PCIe server with 4 or 8 cardsOne server monitor, one row per card, plus fan speed for actively cooled cardsRTX PRO 6000 Blackwell Server Edition verified

For memory or TDP of the individual models, see the NVIDIA data sheets. This page only lists values the agent has measured itself.

Plans and pricing

An HGX server is one server monitor, whether it has four or eight GPUs. Uptime monitors, heartbeats, status pages, channels and NodeCare are included in all plans, NodeGuard from Premium.

Proof of Concept

Free

For testing

  • 1 server monitor
  • 1 uptime monitor, 1 heartbeat
  • 1 status page
  • Data for 14 days
  • NodeCare

Premium Recommended

€149 per month

€1,490 per year

  • 10 server monitors
  • 50 uptime monitors, 50 heartbeats
  • 5 status pages, 1 team
  • Data for 1 year
  • NodeCare and NodeGuard

Enterprise

€490 per month

€4,900 per year

  • 50 server monitors
  • 250 uptime monitors, 250 heartbeats
  • 25 status pages, unlimited teams
  • Data for 1 year
  • NodeCare and NodeGuard

On-Premise

Price on request

Installation package for your own servers

  • No limits on monitors and GPUs
  • All data in your own network
  • NodeCare and NodeGuard
  • one-off, plus VAT

One server monitor is one server, regardless of how many GPUs it has. NodeCare is included in every plan, NodeGuard in Premium, Enterprise and On-Premise. All plans in detail

Set up in three steps

No service, no open port. The server sends, the portal receives.

  1. Create a server monitor

    Sign up, open “Server monitors”, create a monitor for the server, choose the reporting interval and enter 8 as the expected number of GPUs.

  2. Run one line on the server

    The command from the portal downloads the agent script with this server’s token and adds it to the crontab. Run it as root so that the kernel log and the processes of all users can be read.

    mkdir -p -m 700 /opt/peaknode && cd /opt/peaknode && printf 'header = "Authorization: Bearer <TOKEN>"\n' | curl -fsSL -K - "https://peaknode.de/server-monitor-code/<ID>?os=linux" -o peaknode.tmp && mv -f peaknode.tmp peaknode.sh
    chmod 700 peaknode.sh && (crontab -l 2>/dev/null | grep -v peaknode.sh; echo "* * * * * /bin/bash /opt/peaknode/peaknode.sh") | crontab -
  3. Set alerts and channels

    From the first report you see all eight cards. Set thresholds (temperature, memory, idle time), store the electricity price and choose the channels.

Frequently asked
questions about HGX B300 and B200

Continue to:

What does PeakNode monitor on an HGX B300?

Each of the eight GPUs individually: utilization, memory, temperature, power and clock, plus the server totals, hardware errors from the kernel log, idle time and energy. If a card is missing or the server stops reporting, you get an alert.

Is an HGX B300 one server monitor or eight?

One. One server monitor corresponds to one server, regardless of how many GPUs it has. The eight cards appear as rows below it; the plans count servers.

Has this been tested on an HGX B300?

Collection per GPU and the totals across eight cards were verified on an HGX server with 8× H100 SXM. The B300 was tested as a single B300 SXM6 AC with MIG, with values identical to nvidia-smi. A complete HGX B300 uses the same path; a test run on one is still pending.

What is MIG and how do I monitor MIG instances?

MIG (Multi-Instance GPU) splits a data center GPU into separate instances with their own memory. With MIG enabled, nvidia-smi reports no utilization and no memory for the card as a whole. Instead, the agent reads the instances (profile, GPU instance, SM count, memory), and the portal shows them below the card. nvidia-smi does not provide utilization per instance; there the portal shows “-”.

Does PeakNode monitor NVLink and InfiniBand?

NVLink errors appear as Xid 74 from the kernel log. The agent does not collect bandwidth per NVLink or InfiniBand counters.

How accurate is the energy calculation?

It is based on the power that nvidia-smi reports per GPU, added up over the reporting intervals. Shorter intervals give more accurate values. CPUs, power supply losses and cooling are not included.

Which data leaves the server?

The readings as JSON over TLS, with the monitor’s token in the Authorization header. Host names and process names are included, model data or file contents are not. If NodeGuard is switched on for the server, the security data listed on the security page is added. A report is at most 1 MB. The portal cannot execute anything on the server.

Do I need DCGM for an HGX B300?

No. The agent reads all eight GPUs through nvidia-smi and the Xid messages from the kernel log, both of which come with the NVIDIA driver. DCGM profiling metrics such as SM activity are therefore not included. The GPU server monitoring page explains the difference.

What does the BMC provide, and what does the agent provide?

The agent reads the values of the eight GPUs through nvidia-smi and the kernel log. If ipmitool is installed and the server’s BMC is reachable over IPMI, the Linux agent version 11 or later also reads power supplies, fans, inlet temperature and server power every 3 minutes. NodeCare then reports a failed power supply or fan.

Your first HGX server in the portal in five minutes

Create an account, create a monitor, run one line on the server. The Proof of Concept plan is free.